910 resultados para alternative splicing, biomarker, kallikrein-related peptidase, prostate-specific antigen (PSA)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PSA-RP2 is a variant transcript expressed from the PSA gene that is conserved in gorillas, chimpanzees and humans suggesting a particular relevance for this transcript in these primates. We demonstrated by qRT-PCR that PSA-RP2 is upregulated in prostate cancer compared with benign prostatic hyperplasia tissues. The PSA-RP2 protein was not detected in seminal fluid and was cytoplasmically localised but not secreted from LNCaP or transfected PC3 prostate cells, despite secretion from transfected Cos-7 and HEK293 kidney cell lines. PSA-RP2-transfected PC3 cells showed slightly decreased proliferation and increased migration towards PC3-conditioned medium that could suggest a functional role in prostate cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate-specific antigen (PSA) and the related kallikrein family of serine proteases are current or emerging biomarkers for prostate cancer detection and progression. Kallikrein 4 (KLK4/hK4) is of particular interest, as KLK4 mRNA has been shown to be elevated in prostate cancer. In this study, we now show that the comparative expression of hK4 protein in prostate cancer tissues, compared with benign glands, is greater than that of PSA and kallikrein 2 (KLK2/hK2), suggesting that hK4 may play an important functional role in prostate cancer progression in addition to its biomarker potential. To examine the roles that hK4, as well as PSA and hK2, play in processes associated with progression, these kallikreins were separately transfected into the PC-3 prostate cancer cell line, and the consequence of their stable transfection was investigated. PC-3 cells expressing hK4 had a decreased growth rate, but no changes in cell proliferation were observed in the cells expressing PSA or hK2. hK4 and PSA, but not hK2, induced a 2.4-fold and 1.7-fold respective increase, in cellular migration, but not invasion, through Matrigel, a synthetic extracellular matrix. We hypothesised that this increase in motility displayed by the hK4 and PSA-expressing PC-3 cells may be related to the observed change in structure in these cells from a typical rounded epithelial-like cell to a spindle-shaped, more mesenchymal-like cell, with compromised adhesion to the culture surface. Thus, the expression of E-cadherin and vimentin, both associated with an epithelial-mesenchymal transition (EMT), was investigated. E-cadherin protein was lost and mRNA levels were significantly decreased in PC-3 cells expressing hK4 and PSA (10-fold and 7-fold respectively), suggesting transcriptional repression of E-cadherin, while the expression of vimentin was increased in these cells. The loss of E-cadherin and associated increase in vimentin are indicative of EMT and provides compelling evidence that hK4, in particular, and PSA have a functional role in the progression of prostate cancer through their promotion of tumour cell migration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate-specific antigen (PSA) and the related kallikrein family of serine proteases are current or emerging biomarkers for prostate cancer detection and progression. Kallikrein 4 (KLK4/hK4) is of particular interest, as KLK4 mRNA has been shown to be elevated in prostate cancer. In this study, we now show that the comparative expression of hK4 protein in prostate cancer tissues, compared with benign glands, is greater than that of PSA and kallikrein 2 (KLK2/hK2), suggesting that hK4 may play an important functional role in prostate cancer progression in addition to its biomarker potential. To examine the roles that hK4, as well as PSA and hK2, play in processes associated with progression, these kallikreins were separately transfected into the PC-3 prostate cancer cell line, and the consequence of their stable transfection was investigated. PC-3 cells expressing hK4 had a decreased growth rate, but no changes in cell proliferation were observed in the cells expressing PSA or hK2. hK4 and PSA, but not hK2, induced a 2.4-fold and 1.7-fold respective increase, in cellular migration, but not invasion, through Matrigel, a synthetic extracellular matrix. We hypothesised that this increase in motility displayed by the hK4 and PSA-expressing PC-3 cells may be related to the observed change in structure in these cells from a typical rounded epithelial-like cell to a spindle-shaped, more mesenchymal-like cell, with compromised adhesion to the culture surface. Thus, the expression of E-cadherin and vimentin, both associated with an epithelial-mesenchymal transition (EMT), was investigated. E-cadherin protein was lost and mRNA levels were significantly decreased in PC-3 cells expressing hK4 and PSA (10-fold and 7-fold respectively), suggesting transcriptional repression of E-cadherin, while the expression of vimentin was increased in these cells. The loss of E-cadherin and associated increase in vimentin are indicative of EMT and provides compelling evidence that hK4, in particular, and PSA have a functional role in the progression of prostate cancer through their promotion of tumour cell migration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a new concept for rapid and fully portable Prostate Specific Antigen (PSA) measurement, termed “Lab-in-a-Briefcase”, which integrates an affordable microfluidic ELISA platform utilising a melt-extruded fluoropolymer Micro Capillary Film (MCF) containing 10 bore, 200 μm internal diameter capillaries, a disposable multi-syringe aspirator (MSA) plus a sample tray pre-loaded with all required immunoassay reagents, and a portable film scanner for colorimetric signal digital quantitation. Each MSA can perform 10 replicate microfluidic immunoassays on 8 samples, allowing 80measurements to be made in less than 15 minutes based on semi-automated operation and norequirement of additional fluid handling equipment. An assay was optimised for measurement of a clinically relevant range of PSA from 0.9 to 60.0 ng/ml in 15 minutes with CVs in the order of 5% based on intra-assay variability when read using a consumer flatbed film scanner. The PSA assay performance in the MSA remained robust in the presence of undiluted or 1:2 diluted human serum or whole blood, and the matrix effect could simply be overcome by extending sample incubation times. The PSA "Lab-in-a-briefcase" is particularly suited to a low-resource health setting where diagnostic labs and automated immunoassay systems are not accessible, by allowing PSA measurement outside the laboratory using affordable equipment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a new, power-free and flexible detection system named MCFphone for portable colorimetric and fluorescence quantitative sandwich immunoassay detection of prostate specific antigen (PSA). The MCFphone is composed by a smartphone integrated with a magnifying lens, a simple light source and a miniaturised immunoassay platform, the Microcapillary Film (MCF). The excellent transparency and flat geometry of fluoropolymer MCF allowed quantitation of PSA in the range 0.9 to 60 ng/ml with < 7 % precision in 13 minutes using enzymatic amplification and a chromogenic substrate. The lower limit of detection was further improved from 0.4 to 0.08 ng/ml in whole blood samples with the use of a fluorescence substrate. The MCFphone has shown capable of performing rapid (13 to 22 minutes total assay time) colorimetric quantitative and highly sensitive fluorescence tests with good %Recovery, which represents a major step in the integration of a new generation of inexpensive and portable microfluidic devices with commercial immunoassay reagents and off-the-shelf smartphone technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate cancer (PCa) is the most commonly diagnosed non-skin cancer and second leading cause of cancer-related death of men in developed countries. Measurement of prostate specific antigen (PSA) is a very sensitive method for diagnosing and monitoring of prostate cancer (PCa), but the specificity needs improvement. Measurements of different molecular forms of PSA have been shown to improve differentiation between PCa and benign prostatic diseases. However, accurate measurement of some isoforms has not been achieved in previous assays. The aim of the present study was to develop new assays that reliably measure enzymatically active PSA, PSA-α1-chymotryposin (PSA-ACT) and PSA-α1-protease inhibitor (PSA-API), and to evaluate their diagnostic value. Double-label immunofluorometric assays using a novel monoclonal antibody (MAb) and another antibody to either free PSA (fPSA) or total PSA (tPSA) were developed and used to measure PSA-ACT and fPSA or tPSA at the same time. These assays provide enough sensitivity for measurement of PSA-ACT in sera with low PSA levels. The results obtained confirmed that proportion of PSA-ACT to tPSA (%PSA-ACT) was as useful as proportion of fPSA to tPSA (%fPSA) for discrimination between PCa and benign prostatic hyperplasia (BPH). We developed an immunoassay for detection of PSA-API based on proximity ligation, which improved assay sensitivity 10-fold compared with conventional assays. Our results confirmed previous findings that the PSA-API level is somewhat lower in men with than without PCa, and the combination of %fPSA and proportion of PSA-API to tPSA (%PSA-API) provides diagnostic improvement compared with either method alone. Assays based on this principle should be applicable to other immunoassays in which the nonspecific background is a problem. An immunopeptidometric sandwich assay (IPMA) was developed to measure the enzymatically active PSA. This assay showed high specificity, but sensitivity was not good enough for measurement of PSA concentrations in the gray zone, 2-10 µg/L, in which tPSA does not efficiently differentiate between PCa and BPH. We further developed a solid-phase proximity ligation immunoassay, which provided a 10-fold improvement in sensitivity. This proof of concept study shows that peptides reacting with proteins are potentially useful for sensitive and specific measurement of protein variants for which specific MAbs cannot be obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate-specific antigen (PSA) is important in tumour detection, monitoring disease progression and tumour recurrence. however, PSA is not a cancerspecific marker as levels can also be elevated in benign prostatic disease. A number of different mRNA transcripts of PSA have also been identified in prostatic tissue, but have not been fully characterized (PSA 424, PSA 525, Schulz transcript). Tissue specimens from transurethral resection of the prostate (TURP) or radical prostatectomy were obtained from 17 men with BPH and 15 men with prostate cancer. Total RNA was extracted, and reverse-transcriptionpolymerase chain reaction (RT-PCR) and Southern analysis carried out using transcript-specific primers and probes to determine which mRNA PSA transcripts were expressed. Real-time PCR was performed to determine transcript levels between the two groups using transcript-specific primers and SYBR green fluorescence. Values obtained were normalized to a standard housekeeping gene, B2-microglobulin. Transcripts amplified by RT-PCR and real-time PCR were confirmed by DNA sequencing. Our results show that the transcripts were present in some, but not all, BPH and cancer samples indicating that they are not specific to either BPH or cancer. Analysis of real-time PCR normalized values using a Student’s t -test, shows that there is a significant difference between the two groups for PSA 424, but not wild-type PSA, PSA 525 or the Schulz transcript. Although a larger cohort of samples is needed to further confirm these results, these findings suggest that mRNA levels of PSA 424 may have some utility as a diagnostic or prognostic marker in prostate cancer detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First-degree relatives of men with prostate cancer have a higher risk of being diagnosed with prostate cancer than men without a family history. The present review examines the prevalence and predictors of testing in first-degree relatives, perceptions of risk, prostate cancer knowledge and psychological consequences of screening. Medline, PsycInfo and Cinahl databases were searched for articles examining risk perceptions or screening practices of first-degree relatives of men with prostate cancer for the period of 1990 to August 2007. Eighteen studies were eligible for inclusion. First-degree relatives participated in prostate-specific antigen (PSA) testing more and perceived their risk of prostate cancer to be higher than men without a family history. Family history factors (e.g. being an unaffected son rather than an unaffected brother) were consistent predictors of PSA testing. Studies were characterized by sampling biases and a lack of longitudinal assessments. Prospective, longitudinal assessments with well-validated and comprehensive measures are needed to identify factors that cue the uptake of screening and from this develop an evidence base for decision support. Men with a family history may benefit from targeted communication about the risks and benefits of prostate cancer testing that responds to the implications of their heightened risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Els pacients amb càncer presenten una taxa de supervivència superior si es diagnostiquen a estadis inicials, per la qual cosa és indispensable disposar de marcadors tumorals adequats. Glicoformes de proteïnes específiques es podrian utilizar com marcadors tumorals. S’han investigat les subformes i glicosilació de l’Antígen Prostàtic Específic (PSA) per millorar la seva capacitat de diagnosis de pacients amb càncer de pròstata vs aquells amb hiperplàsia benigna prostàtica. També s’han avaluat glicoproteïnes sèriques amb alteracions glucídiques en pacients de càncer de pàncrees, comparat amb pacients amb pancreatitis crònica i controls. S’ha observat una disminució de la fucosilació core i sialilació del PSA en càncer de pròstata i un augment de la fucosilació core i Sialyl-Lewis X en algunes Proteïnes de fase Aguda en càncer de pàncrees. Aquest canvis s’haurien d’avaluar en un cohort de pacients més gran per determinar el seu paper en el cribratge, diagnòstic o monitorització dels cancers estudiats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the intra-individual (physiological) variation of prostate-specific antigen (PSA) measurements in men after a benign prostatic biopsy. Sixty-four men were prospectively assessed, all of whom had a benign prostatic biopsy within the preceding 13 months. The degree of intra-individual variability was established by calculating the coefficient of variation on four PSA levels obtained from each patient weekly over a month. Six patients were subsequently diagnosed with prostate cancer and their data are presented separately. In the remaining 58 patients the median (range) individual mean PSA value was 6.3 (0.5-34.1) ng/mL. The median (range) coefficient of variation within the group was 9.5 (2.4-76.1)%. There was a clear linear relationship between mean PSA level and the standard deviation. In 48 of the 63 patients analysed, the coefficient of variation for serum PSA values in the group as a whole was greater than the variation claimed for the assay technique. The significance of the linear relationship between PSA and the standard deviation is discussed, with particular reference to those men who had a benign prostate biopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.